IMC : fsm not auto extracted/Identified by IMC

Hi,

I've vhdl block containing fsm . IMC not able to auto extract the state machine coded like this:

Snipped of the fsm code:

----------------------------------------------------------------------------------------------------------------------------------------------

               type state_type is (ST_IDLE, ST_ADDRESS, ST_ACK_ADDRESS, ST_READ, ST_ACK_READ, ST_WRITE, ST_ACK_WRITE, ST_IDLE_BYTE);

               signal state : state_type;

               signal state_mux : state_type;

               signal next_state : state_type;

process(state_mux, start)

         begin

               next_state <= state_mux;

               next_count <= (others => '0');

           case (state_mux) is

                 when ST_IDLE => 

                            if(start = '1') then

                                 next_state <= ST_ADDRESS;

                              end if;

            when ST_ADDRESS =>

   …………….

          when others => null;

         end case;

     end process;

 

process(scl_clk_n, active_rstn)

               begin

                      if(active_rstn = '0') then

                           state <= ST_IDLE after delay_f;

                  elsif(scl_clk_n'event and scl_clk_n = '1') then

                             state <= next_state after delay_f;

                            end if;

end process;

 

process(state, start)

               begin

                     state_mux <= state;

               if(start = '1') then

                       state_mux <= ST_IDLE;

                              end if;

               end process;

Pls. Help

Thanks

Raghu

Image may be NSFW.
Clik here to view.

Encryption of IP for Simulation with IES

I'm sending encrypted HDL to a customer who will use Cadence IES for simulation and was wondering how I should go about the encryption.

Does IES support the IEEE's P1735 and if so, where can I find Cadence's public key for performing the encryption?

Or is there an alternative solution that I can use for encryption?

Image may be NSFW.
Clik here to view.

IMC: toggle coverage for package array

Hello!

I have input signal like this  ->  input  wire [ADM_NUM-1:0][1:0] m_axi_ddr_rresp.

When i want to analyze coverage from IMC  this signal not covered!

Can i collect coverage for this signal?

 Image may be NSFW.
Clik here to view.

Image may be NSFW.
Clik here to view.

How do we use the concept of Save and Restore during real developing(debugging)???/

Hi All,

I'm trying to understand checkpoint concept. When I found save and restart concept in cdnshelp, There is just describing about "$save" and "xrun -r "~~~".

and I found also the below link about save restart and it saves your time.

https://community.cadence.com/cadence_blogs_8/b/fv/posts/xcelium-s-new-save-and-restart-saves-you-time

https://community.cadence.com/cadence_blogs_8/b/fv/posts/not-your-uncle-39-s-save-amp-restore-what-xcelium-simulator-brings-to-the-table

But I can't find any benefits from my experiment from save&restart article( I fully agree..the article)

Ok, So I'v got some experiment  Here.

1. I declared $save and got the below result as I expected within the simple UVM code.

In UVM code...

$display("TEST1");
$display("TEST2");
$save("SAVE_TEST");
$display("TEST3");
$display("TEST4");

And I restart at "SAVE_TEST" point by xrun -r "SAVE_TEST", I've got the below log

xcelium> run
TEST3
TEST4

Ok, It's Good what I expected.(The concept of Save and Restore is simple: instead of re-initializing your simulation every time you want to run a test, only initialize it once. Then you can save the simulation as a “snapshot” and re-run it from that point to avoid hours of initialization times. It used to be inconvenient. I agree..)

2. But The Problem is that I can't restart with modified code. Let's see the below example.

I just modified TEST5 instead of "TEST3"

$display("TEST1");
$display("TEST2");
$save("SAVE_TEST");
$display("TEST5"); //$display("TEST3");
$display("TEST4");

and I rerun with xrun -r "SAVE_TEST", then I've got the same log

xcelium> run
TEST3
TEST4

There is no "TEST5". Actually I expected "TEST5" in the log.From here We know $save can't support partially modified code after $save. 

Actually, through this, we can approach to our goal about saving developing time. 

So I want to know Is there any possible way that instead of re-initializing our simulation every time we want to run a test, only initialize it once and keep developing(debugging) our code ?

If we do, Could you let me know the simple example?

Image may be NSFW.
Clik here to view.

Can't collect AXI4 burst_started coverage

I have a problem connected with my AXI4 coverage.

Image may be NSFW.
Clik here to view.

I enable coverage collection in AXI4 

      set_config_int("axi4_active_slave_agent_0.monitor.coverModel", "burst_started_enable", 1);
      set_config_int("axi4_active_slave_agent_0.monitor.coverModel", "coverageEnable", 1);

but i don't have a result.

I think the problem in Callback, but i try to connect all callback and i don't have positive result.

Can you help me?

Image may be NSFW.
Clik here to view.

How to run a regressive test and merge the ncsim.trn file of all test into a single file to view the waveform in simvision ?

Hi all,

         I want to know how to run a regressive test in cadence and merge all ncsim .trn file of each test case into a single file to view all waveform in simvision. I am using Makefile to invoke the test case.

         eg:-

               test0:

                     irun -uvm -sv -access +rwc $(RTL) $(INTER) $(PKG) $(TOP) $(probe) +UVM_VERBOSITY=UVM_MEDIUM +UVM_TESTNAME=test0

             test1:

                   irun -uvm -sv -access +rwc $(RTL) $(INTER) $(PKG) $(TOP) $(probe) +UVM_VERBOSITY=UVM_MEDIUM +UVM_TESTNAME=test1

          I just to call test0 followed by test1 or parallel both test and view the waveform for both tests case.

        I new to this tool and help me with it

                     

Image may be NSFW.
Clik here to view.

Coverage error

Hi  all,

          I am getting this warning in while generating the coverage report, can you help me to clear this warning?

ncsim: *W,COVOPM: Coverage configuration file command "set_covergroup -optimize_model" can be specified to improve the performance and scalability of coverage model containing SV covergroups. It may be noted that subsequent merging of a coverage database saved with this command and a coverage database saved without this command is not allowed.

Image may be NSFW.
Clik here to view.

Developing a solid DV flow : xrun wrapper tool

Hi all,

I need to develop a digital design/verification solution to compile,elaborate and simulate SV designs (basically a complex xrun wrapper). I am an experienced user of xrun and I have done a number of these wrappers over the years but this one is to be more of a tool, intented to be used Company-wise, so it needs to be very well thought and engineered.

It needs to be robust, simple and extensible. It needs to support multi-snapshot elaboration, run regressions on machine farms, collect coverage, create reports, etc.

I've been browsing the vast amount of documentation on XCELIUM and, although very good, I can't find any document which puts together all the pieces of what I am trying to achieve. I suppose I am more clear on the elaboration, compilation and simulation part but I am really lacking on the other areas like : LSF, regressions coverage, where does vManager fits in all this, etc.

I'd appreciate if someone can comment on whether there is a document which depicts how such a DV flow can be put together from scratch, or whether there is a kind of RAK with some example xrun wrapper.

Thanks

Image may be NSFW.
Clik here to view.

Design of DC motor model

xmsim is not exiting the simulation for this error

xmsim is not exiting the simulation for this error. It is unusual for the simulator to not exit for an error. I have just started using uvm and this is occurring during the randomization step for a sequencer item.

xmsim: *E,RNDCNSTE

I am using -EXIT on the command line.

I am using Xcelium 19.03-s013.

Any insights are appreciated. Thanks.

-Jim

Image may be NSFW.
Clik here to view.

Xcelium Probe -Screen Issue

Hi All,

I want to capture the transition values of certain nodes in a design (i.e. a digital multiplier built with standard cells) and I use probe -screen command to dump the nodal values in text format. Since I only need to capture these values in the ideal situation, I use -nospecify switch with the xrun command :

xrun -clean R16FA_2009.v R4BE_Test.v tb_stop16.v -v stdlib_verilog_models-sdf30.v -access +rwc -mess -timescale 1ns/1ps -nospecify -gui &

and the probe command goes like this : 

probe -screen tb_stop16.mul16.test.L1 -redirect probe1.txt -format "%T L1 Value: %b"  //Here L1 is an array of wires

Although I expect a single transition at a given time instance, I see multiple transitions occurring in the dumped probe1.txt file. i.e. 

Time: 300 PS : 48'bxx0xx0xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx0xx0xx11x
Time: 300 PS : 48'b000000000000000000000000000000000000000000000110
Time: 4 NS : 48'b001000000000000000000000000000000000000000000100
Time: 4 NS : 48'b011000000010111111111001000000110011011001010101
Time: 8 NS : 48'b010000000010111111111001000000110011011001010101
Time: 8 NS : 48'b110100101100000110000111100001010010111001011100
Time: 12 NS : 48'b010000110011100010001110011100010101010001010101
Time: 16 NS : 48'b000010000010000000000000000010000000010010010100
Time: 20 NS : 48'b000011000010000000000000000010000000010010010100
Time: 20 NS : 48'b000001001001001001011011000010001010011010010100

From the waveform, it appears that only the second value (bold)  of the time instance is correct. Since the simulation is without annotated delays, there are no intermediate transitions in the waveform. How could this be possible ?

Thanks in advance

Image may be NSFW.
Clik here to view.

Info regarding released version Cadence IES simulator

Hello folks,

 

Greetings.

 

One of my customer claims that he is using Cadence IES version 18.09.011 with Vivado 2019.2. The version of IES that we officially support with Vivado 2019.2 is 15.20.073. Though the tool is forward compatible, I am not sure what are the versions of IES that are released after 15.20.073. Could you please give me a list of the versions of Cadence IES released after 15.20.073 and which is the latest version as of now ?

 

Best regards,

Chinmay

 

Image may be NSFW.
Clik here to view.

Running xrun command in vsif file

Hi,

I found a basic Specman E/Verilog program at http://www.asic-world.com/examples/specman/memory.html and I would like to run it through a vsif file, with vManager.

I'm able to run it, without problems, with this command : xrun -Q -unbuffered '-timescale' '1ns/1ns' '-access' '+rw' memory_tb.v mem_tb_top.e test_write_read_all.e.

I wrote a first vsif which look like this:

---- vm_basic.vsif -----

session vm_basic {
        top_dir : /home/cadence/xrunTest/;
        output_mode: terminal;
};

group basic {
        test test {
                run_script: xrun -Q -unbuffered '-timescale' '1ns/1ns' '-access' '+rw' memory_tb.v mem_tb_top.e test_write_read_all.e
        };
};

----------------------------

This solution didn't work due to the prompt change with xrun, and I have no clue how to manage this issue.

Have you any idea?

Best regards,

Yohan

Image may be NSFW.
Clik here to view.

Incisive Metrics Center User Guide

Hi Team,

I would like to download "Incisive Metrics Center User Guide", I could not find in the cadence/support/manuals. Can you please provide me the link or path to download the same ? I am doing functional coverage with IMC. 

Thank You,

Mahesh

Image may be NSFW.
Clik here to view.

How to refer the library compiled by INCISIVE 13.20 in Xcelium 19.30

Hi,

I am facing this elaboration error when using Xcelium:

Command>

    xmverilog -v200x +access+r +xm64bit -f vlist -reflib plib -timescale 1ns/1ps

Log>

    xmelab: *E,CUVMUR (<name>.v,538|18): instance 'LUTP0.C GLAT3' of design unit 'tlatntscad12' is unresolved in 'worklib.LUTP0:v'.

I guess the plib was not referred to as the simulation configuration because the tlatntscad12 is included in plib.

The plib is compiled by INCISIVE 13.20 and I am using the Xcelium 19.30.

Please tell me the correct command on how to refer to the library directory compiled by different versions.

Thank you,

Image may be NSFW.
Clik here to view.

How to remove sessions from vManager without deleting them

I am importing sessions which are run by other people to analyse and I would like to remove them from my vManager Regressions tab as they become obsolete. As I am not the original person who run the sims, I cannot "delete" sessions. What are my options? Thanks.

Image may be NSFW.
Clik here to view.

Is it possible to get a diff between two coverage databases in IMC?

I'm in the process of weeding a regression test list. I have a coverage database from the full regression list and would like to diff it with the coverage database from the new reduced regression test list. If possible I would than like to trace back any buckets covered with the full list, but not with the partial list, into the original tests that covered them.

Is that possible using IMC? if not, is it possible to do from Specman itself?

(Note that we're not using vManager)

Thanks,

Avidan

Image may be NSFW.
Clik here to view.

search for glob/regexp in specman loaded modules?

Specman *search* command allows searching in all loaded modules, but only for a string.

Is there a way to search for a regexp or glob?

Alternatively, is there a way to simply get a list of all loaded files somehow? Then I could use either the "shell" command, or real shell together with grep.

Thanks

Image may be NSFW.
Clik here to view.

XmVlog - *F,DIRDEC error

I'm trying to compile a simple verilog file using xmvlog. I run the following command,

"xmvlog myfile.v"

Then I get the following error,

"xmvlog: *F,DIRDEC: Can't save decompressed versions of compressed files."

I used to use xmvlog with no issues, this error started to come up now. The message is not helpful either. How can I solve this?

I appreciate any help, thanks in advance.

Image may be NSFW.
Clik here to view.

Agenter - Professional Network for Commission

Agenter is an Online Professional Networking Platform for Commission, where business profiles present their sales requirements on a commission basis and offer a new way of employment opportunities to every common man and sales agent, to connect and earn a commission. 

Agenter is the best place for anyone who wants to earn money online. Here you can make money in the form of commission by working for the business offers or referring them to the right individuals. You can also help others to make money online by referring to the leads.

How to make money

Make Money Online

Image may be NSFW.
Clik here to view.
Viewing all 1088 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>