购买本科硕士文凭学历认证Q微29304199加拿大蒙特埃里森大学文凭〈UDE毕业证成绩单〉留信认证/蒙特埃里森大学学位证书毕业证offer改GPA成绩雅思...
购买本科硕士文凭学历认证Q微29304199加拿大蒙特埃里森大学文凭〈UDE毕业证成绩单〉留信认证/蒙特埃里森大学学位证书毕业证offer改GPA成绩雅思TOEFL成绩单WSE认证教留服认证Mount Allison...
View Article购买本科硕士文凭学历认证Q微29304199加拿大尼亚加拉学院文凭〈NC毕业证成绩单〉留信认证/尼亚加拉学院学位证书offer改GPA成绩雅思TOEFL成...
购买本科硕士文凭学历认证Q微29304199加拿大尼亚加拉学院文凭〈NC毕业证成绩单〉留信认证/尼亚加拉学院学位证书offer改GPA成绩雅思TOEFL成绩单offerWSE认证教留服认证Niagara...
View ArticleVmanager and the logs tab page
Hello,I am trying to find out if it is possible to modify the files opened in the logs tab.Indeed I want to add a file that is generated by a script, how can I proceed?Thanks you
View ArticleIMC Question : Multiple Coverage Entities
Hi,I am observing in IMC that certain assertions are shown with attribute of "MIX" in red -> multiple coverage entitiesWhat is the meaning of multiple coverage entities attribute in IMC for a...
View ArticleCross coverage of two covergroups
Hello All I want to cross-coverage between two different covergroup, Is it possible to do this? Does the Cadence tool have this feature?`
View ArticleROM design
I am trying to write verilog code to store 2^36 outputs of C432 benchmark circuit in ROM. It is taking more than 3 days to write all the address, still I haven't completed the code. Can you please...
View ArticleIs there a way to view what line of HDL code is being executed at the moment...
I'm trying to run a behavioral simulation of my Verilog design, but somehow the Xmsim simulator seems to go into an infinite loop and the simulation stops advancing. It literally gets stuck. I was...
View Articlegetting xrun to quit on error during simulation
We have a need for xrun to exit during the simulation step of our system verilog design when an error occurs. The error we want to exit on is generally from an assertion (*E,ASRTST) but also could be...
View Articleblack box in the lec cause the mismatch
I use the module from Synopsys in my own module, and those modules become BlackBox dring the lec and cause the not-mapped points. Can anyone tell me how to solve this?
View ArticleIEEE float radix in Simvision
I want to view some signal values in floating-point format in the waveform window. I can easily change the radix to hex, decimal, binary or octal; but there is no option to change to float. How can I...
View ArticleEnable probes via tcl script at certain time or event
I am simulating a big AMS chip, and would like to enable some analog probes via a tcl script just after a certain digital signal, to prevent unnecessary probes before a crucial event.Does anyone know...
View Article$fscanf: reading a file and extracting a particular word or string or args
Hi All,I am trying to read irun.log and if particular match found, I need to write to the new file. Getting compilation error when using $scanf;fp = $fopen("irun.log", "r"); //open file in read...
View ArticleQuestion: How to use -incdir with reg_verifier
Hi,I used reg_verifier to generate register model from one XML IP-XACT.but how I can use the reg_verifier with -incdir option to select more than one XML as input? anyone can help?
View ArticleHow do I map signal values to meaningful string in simvision?
i.e. how do I do something like what's described here for the competition:electronics.stackexchange.com/.../is-there-a-way-to-define-enumeration-for-certain-signals-after-simulation(I'd like to do this...
View ArticleI would like to see the values of a signal after some mathematical/logical...
Looking for a way to run a TCL procedure over all values of a signal, and if possible display these values in the wave on another "virtual" signal.For example:I would like to do the following...
View ArticleHow do I make Denali AXI VIP print summary of the bursts it got/sent during a...
The Denali AHB VIP seems to have a very useful functionality where it prints the number of bursts that it saw in a given test at the end...i.e.*Denali* [5 ms]...
View ArticleIMC exception on opening .ucm from xrun coverage generation
Hello everyone,I am currently working on the xcelium 20.09 integrated coverage online course. To generate the code coverage results, I was able to run the xrun command successfully. However, when...
View ArticleGetting a signal value using simvision TCL
Is that possible?Couldn't find the right command.
View ArticleHow to check if signal top.moduleA.aaa is directly connected to...
Note that I'm not looking for contributors, because these could be going through some logical function. Looking for direct connections.In a big design it is very helpful, for example for figuring out...
View ArticleGetting the Signal Waveforms into the Waveform Window with Xrun Command
Dear All,In Simvision, I want to load the saved signal names (not historical database values) of a design, when running a new simulation. Usually what I do is : xrun -clean ASYNC_FILTER.v...
View Article